  220vac input/12w output non-isolated ac/dc converter with built-in zero cross signal output BP5013 data sheet absolute maximum ratings electrical characteristics conversion efficiency conversion efficiency (vi=-141v, r2= open, ta=25 c ) output current io (ma) conversion efficiency (%) dimensions (unit : mm) external component specifications f1: fuse use a fast-acting fuse of 2.0a. c1: input capacitor c2: output capacitor c3: noise removal capacitor r3 : noise removal resistor d1: rectifier diode d2: flywheel diode r1: pull-up resister r2: output voltage setting resistor znr: varistor please verify operation and characteristics in the customer's circuit before actual usage. ensure that the load current does not exceed the maximum rating. derating curve derating curve 0 6 8 2 4 10 12 14 0 10 -30 -20 -10 20 4030 80706050 90 100 ambient temperature ta ( c ) output power (w) application circuit 100 90 80 70 60 50 40 30 20 10 0 400 2000 600 800 1000 load regulation output voltage settings input voltage zero-cross input voltage operating temperature range storage temperature range maximum surface temperature maximum output power parameter symbol limits unit vi v1 topr tstg tsmax po ?170 120 ?20 to +85 ?25 to +105 105 12 v vrms c c c w unit ?2 ?1 conditions v v ma v v vp-p % v v dc ? ? vi= ?113 to ?170v io=0 to 1000ma ? ? v1 = ?141v v1=0v ? 1 max output current should be reduced according to the surrounding temperature. ? 2 the output ripple voltage may vary depending on the capacitance, environment, and location of peripheral components. input voltage range output voltage output current line regulation load regulation output ripple voltage power conversion efficiency zero-cross signal h zero-cross signal l parameter symbol ty p. max. min. vi vo io vr vl vp vzh vzl ?141 ?12 ? 0.03 0.13 0.22 83 ? ?5.0 ?170 ?13 1000 0.2 0.2 0.35 ? ?0.3 ?5.3 ?113 ?11 ? ? ? ? 75 0 ?4.6 (unless otherwise specified, ta=25 c, vi= ? 141v, io=1000ma, v2=? 5v,r1=10k ? ) (vo=12v, r2=open) operation range operation range pin no. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 function zero-cross input 1 (acin) skip input (vi) skip skip coil 1 (coil-1) skip coil 2 (coil-2) output (vo) adj (voadj) common test zero-cross signal output (zcout) zero-cross signal input (-5v) (zc) rated voltage : beyond 250v, capacitance : 47 to 220 f rated ripple current : 0.22arms or higher rated voltage : please ensure a rated voltage (whose value is proportional to the output voltage) with sufficient margin capacitance : 330 to 1000 f, low impedance type esr : less than 0.08 ? rated ripple current : byond 1.0arms evaluate under actual operating conditions since it affects the output ripple voltage. rated voltage : beyond 250v, capacity : 0.1 to 0.22 f film or ceramic capacitor resistance : 10 to 22 ? , power : more than 1/4w peak reverse voltage : more than 400v mean rectifying current : more than 1.0a peak forward surge current : more than 20a full-wave rectification can be used. peak reverse voltage : more than 400v mean rectifying current : more than 3.0a, fast recovery diode please note that both the switching and efficiency characteristics of the module are affected by this diode. recommended products : rf2001t4s (rohm), 31df4 (nihon inter), ru30 (sanken). inductance : 330 h (vo=-12v) rated current : more than 1.3a please refer to the output voltage settings table to the right. a varistor is required to protect against lightning surges and static electricity. 10k? 1/10w refer to the output voltage settings table to the right. l1: power inductor vo io r2 l1 open 75k? 8.2k? 1.8k? 330h 470h 1mh 1mh 1000ma 800ma 500ma 400ma ?12v ?15v ?24v ?30v 9 10 11 r2 + ? vo voadj com 12k ? 47k ? 36k ? vref=6.9v 9 11 output block diagram 23.2max. marking side 4.0 1.0 38.5max. 11.2max. 3.65 max. 7.55 max. 2.54 ? 13=33.02typ 2.54 0.2 0.5 0.1 1.3 0.2 0.25 0.05 3.25max 1 3 6 8 9 10 13 14 1211 (vi=-141v, r2= open, ta=25 c ) load regulation -14.0 -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 output current io (ma) output voltage vo (v) 2000 400 600 800 1000 1200 1400 maximum io=1000ma maximum io=1000ma 1 3 6 8 9 10 11 12 13 + + 14 vo io v 2 =?5v r3 c3 c1 c2 r2 r1 l1 d2 znr d1 ac100v f1 1 3 6 8 9 + + ? ? 1 4 BP5013 c1 l1 znr zero-cross signal coil start be sure to use a fuse for safety 100vac input/ ? 5vdc (200ma) output non-isolated ac/dc converter with built-in zero cross signal output bp5011 data sheet absolute maximum ratings electrical characteristics conversion efficiency dimensions (unit : mm) derating curve load regulation input voltage zero-cross input voltage operating temperature range storage temperature range maximum surface temperature maximum output current parameter unit conditions ? 1 max output current should be reduced according to the surrounding temperature. ? 2 spike noise is not included in output ripple voltage. input voltage range output voltage output current line regulation load regulation output ripple voltage power conversion efficiency zero-cross signal h zero-cross signal l parameter symbol typ. max. min. symbol limits unit vi v1,v2 topr tstg tsmax io ?170 120 ?20 to +85 ?25 to +105 105 200 v vrms c c c ma ?2 ?1 v v ma v v vp-p % v v dc ? ? vi= ?85 to ?170v io=0 to 200ma io=200ma io=200ma v1, v2=2.3v, r z 1, 2=4k ? v1, v2= ? 5.3v, r z 1, 2=4k ? ?141 ?5.0 ? 0.01 0.01 0.06 68 ? ?5.0 ?170 ?5.3 200 0.15 0.15 0.15 ? ?0.3 ?5.3 ?85 ?4.7 ? ? ? ? 60 0 ?4.4 vi vo io vr vl vp v z h v z l (unless otherwise noted, ta=25c,vi= ? 141v, lo=100ma) 17.4max. mark side 4 1.0 35.1max. marking side 8.1max. 4.5max. 3.6max. 2.54 ? 12=30.48typ 2.54 0.2 0.5 0.1 1.3 0.2 0.25 0.05 3.0max 21 3 4 5 7 9 11 13 derating curve 0 50 100 150 200 250 0 10 -30 -20 -10 20 4030 80706050 90 ambient temperature ta ( c ) output current io (ma) conversion efficiency (vi= ? 141 v,ta=25 c ) (vi= ? 141 v,ta=25 c ) output current io (ma) conversion efficiency (%) 100 90 80 70 60 50 40 30 20 10 0 50 0 100 150 200 load regulation 6.0 5.0 4.0 3.0 2.0 1.0 0.0 output current io (ma) output voltage ? vo (v) 500 100 150 200 250 300 operation range operation range maximum lo=200ma maximum lo=200ma external component specifications f1: fuse use a fast-acting fuse of 1.0a. rated voltage : 250v or higher capacitance : 22 to 100 f rated voltage : 250v or higher capacitance : 0.1 to 0.22 f film or ceramic capacitor c1: input capacitor c2: output capacitor rated voltage : 10v or higher capacitance : 100 to 470 f, low impedance type esr : less than 0.16 ? rated ripple current : beyond 0.58arms evaluate under actual operating conditions since it affects the output ripple voltage. c3: noise removal capacitor inductance : 560 h rated current : more than 0.52a l1: power inductor resistance : 10 to 22 ? power : more than 1/4w pull-up resistor for zero-cross signal. 4k ? 1/10w r1: noise removal resistor r2,r3 : pull-up resistor a varistor is required to protect against lightning surges and static electricity. znr : varistor peak reverse voltage : more than 400v mean rectifying current : more than 1.0a peak forword surge current : more than 20a full-wave rectification can be used. d1: rectifier diode please verify operation and characteristics in the customer's circuit before actual usage. ensure that the load current does not exceed the maximum rating. application circuit pin no. 1 2 3 4 5 6 7 8 9 10 11 12 13 function zero-cross signal output2(vz2) zero-crosssignal output1 (vz1) output (vo) common coil 1 (coil-1) skip coil 2 (coil-2) skip input (vi) skip zero-cross input2 (acin2) skip zero-cross input1 (acin1) r3 r2 vo znr + c2 l1 + c1 d1 c3 f1 r1 bp5011 3 5791113 2 1 zero-cross signal1 zero-cross signal2 be sure to use a fuse for the safety. 4 coil start 1/1 2010.01 - rev.a www.rohm.com ?2010 rohm co., ltd. all rights reserved.


r1010 a www.rohm.com ? 2010 rohm co., ltd. all rights reserved. notice rohm customer support system http://www.rohm.com/contact/ thank you for your accessing to rohm product informations. more detail product informations and catalogs are available, please contact us. notes no copying or reproduction of this document, in part or in whole, is permitted without the consent of rohm co.,ltd. the content specied herein is subject to change for improvement without notice. the content specied herein is for the purpose of introducing rohm's products (hereinafter "products"). if you wish to use any such product, please be sure to refer to the specications, which can be obtained from rohm upon request. examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the products. the peripheral conditions must be taken into account when designing circuits for mass production. great care was taken in ensuring the accuracy of the information specied in this document. however, should you incur any damage arising from any inaccuracy or misprint of such information, rohm shall bear no responsibility for such damage. the technical information specied herein is intended only to show the typical functions of and examples of application circuits for the products. rohm does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by rohm and other parties. rohm shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. the products specied in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, ofce-automation equipment, commu- nication devices, electronic appliances and amusement devices). the products specied in this document are not designed to be radiation tolerant. while rohm always makes efforts to enhance the quality and reliability of its products, a product may fail or malfunction for a variety of reasons. please be sure to implement in your equipment using the products safety measures to guard against the possibility of physical injury, re or any other damage caused in the event of the failure of any product, such as derating, redunda ncy, re control and fail-safe designs. rohm shall bear no responsibility whatsoever for your use of any product outside of the prescribed scope or not in accordance with the instruction manual. the products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospac e machinery, nuclear-reactor controller, fuel- controller or other safety device). rohm shall bear no responsibility in any way for use of any of the products for the above special purposes. if a product is intended to be used for any such special purpose, please contact a rohm sales representative before purchasing. if you intend to export or ship overseas any product or technology specied herein that may be controlled under the foreign exchange and the foreign trade law, you will be required to obtain a license or permit under the law.


▲Up To Search▲   

 
Price & Availability of BP5013

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X